作者:admin來源:http://cmicroentropy.com/時間:2022-06-24

全自動超聲波清洗機(jī)具有不傷工件、清潔范圍廣、清洗干凈徹底、綠色、節(jié)省人工等優(yōu)勢,大大提高了清洗工作效率。下面來介紹超聲波清洗儀器九點操作注意事項。
The full-automatic ultrasonic cleaning machine has the advantages of no damage to the workpiece, wide cleaning range, thorough cleaning, green environmental protection and labor saving, which greatly improves the cleaning efficiency. Here are the nine points for attention in the operation of ultrasonic cleaning instrument.
1.超聲波清洗機(jī)應(yīng)處在干燥、通風(fēng)、潔凈的工作環(huán)境中。遠(yuǎn)離熱源,避免放置在潮濕的環(huán)境中。
1. the ultrasonic cleaning machine shall be in a dry, ventilated and clean working environment. Keep away from heat sources and avoid placing in a humid environment.
2.定期清理清洗槽、儲液槽內(nèi)的污垢,保持儀器內(nèi)外潔凈。
2. regularly clean the dirt in the cleaning tank and liquid storage tank to keep the inside and outside of the instrument clean.
3.電氣控制箱及設(shè)備通風(fēng)口要避免濺入液體,并遠(yuǎn)離水蒸氣、粉塵、腐蝕性氣體等,定期清理灰塵。
3. avoid splashing liquid into the electrical control box and equipment vent, keep away from water vapor, dust, corrosive gas, etc., and clean the dust regularly.
4.帶有過濾裝置的超聲波清洗機(jī),要定期更換濾芯。
4. for ultrasonic cleaning machine with filtering device, the filter element shall be replaced regularly.
全自動超聲波清洗機(jī)
5.帶有傳動機(jī)構(gòu)的超聲波清洗機(jī),要定期注入潤滑油,確保傳動機(jī)件在良好潤滑條件下工作。
5. the ultrasonic cleaning machine with transmission mechanism shall be regularly injected with lubricating oil to ensure that the transmission parts work under good lubrication conditions.
6.對于易老化的電氣組件定期進(jìn)行檢查,定期測試設(shè)備的絕緣性能。
6. regularly inspect the electrical components that are prone to aging and regularly test the insulation performance of the equipment.
7.儀器連續(xù)工作不得超過4個小時,如連續(xù)工作時間過長,應(yīng)旋轉(zhuǎn)超聲調(diào)節(jié)旋鈕“0”位,讓散熱風(fēng)扇繼續(xù)工作,以保證電源內(nèi)部熱量散出,讓儀器稍做休整后再使用。長時間運(yùn)行后,關(guān)閉儀器前,也應(yīng)照此操作,讓儀器先將內(nèi)部熱量散出再關(guān)機(jī)。散熱一般需要3~5分鐘。
7. the continuous operation of the instrument shall not exceed 4 hours. If the continuous operation time is too long, the ultrasonic adjustment knob shall be rotated to "0" position to allow the cooling fan to continue to work, so as to ensure that the internal heat of the power supply is dissipated, and the instrument can be used after a slight rest. After long-time operation, the instrument shall also be operated according to this operation before shutting down, so that the instrument can dissipate the internal heat before shutting down. Heat dissipation generally takes 3-5 minutes.
8.定期讓油泵運(yùn)轉(zhuǎn)一次,每次少在10分鐘以上。
8. run the oil pump regularly for at least 10 minutes each time.
9.長時間不用時,用罩子將全自動超聲波清洗機(jī)罩起來,做好防潮防塵。
9. when it is not used for a long time, cover the full-automatic ultrasonic cleaning machine with a cover to prevent moisture and dust.